Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Hinen
  4. BH7700B

Home battery · Hinen · CEC approved October 2024

Hinen BH7700B

A 15.36 kWh home battery.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
15.36kWhBetween the smaller home and medium home bands
Warranty
5yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

BH7700B: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

What we can tell you

Read from the figures on this page. No review written yet.

  • 15.36 kWh sits between the smaller home (10 to 15 kWh) and medium home (20 to 30 kWh) bands.
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
15.36kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the energy you store comes back out
Warranty
5yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Warranty and support

This warranty covers defects in workmanship and materials for five years from the date of installation. Exclusions include improper installation and maintenance, and claims can be made by submitting specific documentation.

Product
5 years; transferable; full replacement
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 2 years on the CEC list. Confirm the claim process with your installer.
Perth heat
Rated to 53°C, which covers Perth's hottest days.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Hinen NA, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Nominal capacity
15.36 kWh
Usable capacity
15.36 kWh

Physical

IP rating
IP67

Operating environment

Operating temperature
98°C to 53°C

Installation requirements

Cable gauge
4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetOpens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

Fault & error codes — Hinen NA

Extracted from the installation manual

26 documented

Showing 26 of 26. The official install manual is the authoritative source — always confirm before acting.

  • Error 108criticalCall your installer
    Manual (PDF)

    Temperature too high

    Likely cause
    Inverter overheating
    What to do
    Check temperature and restart the inverter if normal.
  • Error 109criticalCall your installer
    Manual (PDF)

    Bus voltage abnormal

    Likely cause
    Improper voltage input
    What to do
    Restart inverter.
  • Error 110criticalCall your installer
    Manual (PDF)

    Communication fault

    Likely cause
    Faulty wiring on the communication board
    What to do
    Check communication board wiring and restart if necessary.
  • Error 116criticalCall your installer
    Manual (PDF)

    GFCI Module damage

    Likely cause
    Ground Fault Circuit Interrupter malfunction
    What to do
    Check leakage current module and restart inverter if necessary.
  • Error 206criticalCall your installer
    Manual (PDF)

    Leakage current too high

    Likely cause
    Ground fault
    What to do
    Restart inverter and check for wiring issue.
  • Error 207criticalCall your installer
    Manual (PDF)

    DCI too high

    Likely cause
    Excess current input or short circuit
    What to do
    Restart inverter.
  • Error 208criticalCall your installer
    Manual (PDF)

    AC active power too high

    Likely cause
    Load is exceeding inverter specification
    What to do
    Reduce EPS load.
  • Error 210criticalCall your installer
    Manual (PDF)

    Phase difference too big

    Likely cause
    Mismatched phase connections
    What to do
    Restart inverter and check wiring.
  • Error 300criticalCall your installer
    Manual (PDF)

    EPS OP short fault

    Likely cause
    Short in EPS output
    What to do
    Restart inverter.
  • Error 304criticalCall your installer
    Manual (PDF)

    EPS port voltage abnormality

    Likely cause
    Faulty wiring or faulty EPS port
    What to do
    Check wiring of EPS port.
  • Error 401criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value

    Likely cause
    Excessive voltage input
    What to do
    Disconnect DC switch and check voltage.
  • Error 402criticalCall your installer
    Manual (PDF)

    PV isolation low

    Likely cause
    Faulty PV panel grounding
    What to do
    Check PV panel grounding.
  • Error 403criticalCall your installer
    Manual (PDF)

    The DC input current is exceeding the maximum tolerable value

    Likely cause
    Incompatible PV input
    What to do
    Check PV panel connections.
  • Error 500criticalCall your installer
    Manual (PDF)

    BMS Communication fault

    Likely cause
    Faulty BMS connection
    What to do
    Check 485 cable between SP and battery.
  • Error 505criticalCall your installer
    Manual (PDF)

    Battery terminals reversed

    Likely cause
    Incorrect battery connection
    What to do
    Check battery terminal connections.
  • Error 506criticalCall your installer
    Manual (PDF)

    Battery terminal open (only for lithium battery)

    Likely cause
    Open circuit on battery.
    What to do
    Check battery terminal connections.
  • Error 508criticalCall your installer
    Manual (PDF)

    Bat Relay Fault

    Likely cause
    Faulty relay on battery connection
    What to do
    Restart inverter.
  • Error 113warningCall your installer
    Manual (PDF)

    Over current protected by software

    Likely cause
    Exceeding the current limit
    What to do
    Restart inverter.
  • Error 114warningCall your installer
    Manual (PDF)

    Over current protected by software

    Likely cause
    Exceeding the current limit
    What to do
    Restart inverter.
  • Error 121warningCall your installer
    Manual (PDF)

    Buck boost current abnormal

    Likely cause
    Current fluctuation detected
    What to do
    Restart inverter.
  • Error 123warningCall your installer
    Manual (PDF)

    BUS balance current abnormal

    Likely cause
    Bus system imbalances
    What to do
    Restart inverter.
  • Error 124warningCall your installer
    Manual (PDF)

    DCAC soft abnormal

    Likely cause
    Issues with DC to AC conversion
    What to do
    Restart inverter
  • Error 502warningCall your installer
    Manual (PDF)

    Battery voltage low

    Likely cause
    Battery discharging excessively
    What to do
    Check battery voltage.
  • Error 503warningCall your installer
    Manual (PDF)

    Battery Voltage High

    Likely cause
    Battery overcharge
    What to do
    Check battery voltage and restart.
  • Error 504warningCall your installer
    Manual (PDF)

    Battery temperature out of specified range for charge or discharge

    Likely cause
    Battery overheating
    What to do
    Check battery temperature.
  • Error 125info
    Manual (PDF)

    The inverter is not turned on

    Likely cause
    Inverter power switch is off
    What to do
    Turn on the inverter.

About Hinen

Years on the CEC list
2+ (CEC-approved products since 2024)
Local support
Available
CEC-listed products
39 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$3,990

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery sits between the smaller home and medium home bands. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 15.36 kWh battery

How it compares

The Hinen BH7700B against the closest-sized batteries from other brands.

Specification
Hinen BH7700BHinen
BYD Battery-Box Premium LVL15.4BYD
CALB CJ160F15AACALB
Usable capacity?15.36 kWh15.36 kWh15.36 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?Not verifiedNot verifiedNot verified
Warranty5 yearsNot verifiedNot verified
ChemistryLFPLFPLithium-ion

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from Hinen

Other CEC-approved products from Hinen available in Australia.

Hinen Inverters

A10000S

9.999 kW

A10000S-E

9.999 kW

A10000T

9.999 kW · 3φ

A10000T-E

9.999 kW · 3φ

A15000T

15 kW · 3φ

A15000T-E

15 kW · 3φ

View all Hinen inverters
View full Hinen manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?