Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Atmoce
  4. M-ELV Battery series
  5. MS-7K-U-1P + MC100PRO-S1P

Home battery · Atmoce · M-ELV Battery series · CEC approved April 2026

Atmoce MS-7K-U-1P + MC100PRO-S1P

CEC listing: MS-7K-U-1P + MC100PRO-S1P (AS4777-2 2020)

A 7 kWh home battery with backup power.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
7kWhBelow the smaller-home band
Warranty
25yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MS-7K-U-1P + MC100PRO-S1P: the short answer

In the M-ELV Battery seriesUsable capacity
7kWhUsable capacity
WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Continuous powerRuns most of a home, but not everything at full tilt
5kWRuns most of a home, but not everything at full tilt

The M-ELV Battery series

  • See the whole series →

What we can tell you

Read from the figures on this page. No review written yet.

  • 7 kWh is below the smaller-home band.
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
7kWh
How much energy it stores for you to use
Continuous power
5kW
How much it can run at once: most of a home, but not everything at full tilt
Round-trip efficiency
90%
How much of the energy you store comes back out
Depth of discharge
80%
How much of the battery you can actually use
Warranty
25yr
How long the manufacturer stands behind it
Battery chemistry
Lithium Iron Phosphate(LFP)
Lithium iron phosphate, the long-cycle-life type

Warranty and support

The warranty covers defects in materials and workmanship for five years from the purchase date. Important exclusions include damage from unauthorized repairs and certain environmental conditions. To make a claim, contact support with proof of purchase.

Product
25 years; transferable; pro-rata
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Not verifiedWe have not verified this brand's Australian support structure. Confirm warranty arrangements with the manufacturer or your installer.
Perth heat
Rated to 55°C, which covers Perth's hottest days.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Atmoce M-ELV Battery, by section.

Cell & chemistry

Chemistry
Lithium Iron Phosphate(LFP)
Cell type
LFP

Capacity & power

Nominal capacity
7 kWh
Usable capacity
7 kWh
Continuous power
5 kW
Peak power
5 kW
Depth of discharge
80%
Round-trip efficiency
90%
Nominal voltage
25.6 V

Lifespan & degradation

Cycle life
10000 cycles

Modularity & stacking

Modular / stackable
No
Maximum stack
126 kWh

Backup & grid services

Backup capable
Yes
VPP ready
No

Physical

Dimensions (H×W×D)
830 × 480 × 195 mm
Weight
73.5 kg
IP rating
IP66

Operating environment

Operating temperature
-20°C to 55°C

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • Datasheet and warranty terms and compliance certificateOpens in a new tab
  • Installation guide and user manualOpens in a new tab

Fault & error codes — Atmoce M-ELV Battery

Extracted from the installation manual

22 documented

Showing 22 of 22. The official install manual is the authoritative source — always confirm before acting.

  • 13criticalCall your installer
    Manual (PDF)

    Distribution error occurred

    Likely cause
    Abnormal phase in the single-phase system or phase loss in the three-phase system.
    What to do
    Check for a short circuit in the AC input or for phase loss, reversed phase sequence, or short circuits in the AC wiring. If the alert persists, contact your distributor or Customer Service.
  • 2critical
    Manual (PDF)

    Grid Power Outage

    Likely cause
    Grid power outage occurred.
    What to do
    Check whether the grid is normally powered. Check whether the alternating current cable or breaker is disconnected.
  • 50criticalCall your installer
    Manual (PDF)

    Battery Overvoltage

    Likely cause
    The total battery voltage or battery cell voltage exceeds the alert threshold.
    What to do
    In the app, shut down the battery and then power it on again; Reset the system in the app; If the battery is connected to the grid, disconnect the AC input, wait for the battery indicator to go out, and then restore the AC input; If the alert persists, contact your distributor or Customer Service.
  • 51criticalCall your installer
    Manual (PDF)

    Battery Undervoltage

    Likely cause
    The total battery voltage is below the alert threshold.
    What to do
    If the battery is connected to the grid, disconnect the AC input, wait for the battery indicator to go out, and then restore the AC input; Reset the system in the app; If the alert persists, contact your distributor or Customer Service.
  • 52criticalCall your installer
    Manual (PDF)

    Large Battery Cell Voltage Difference

    Likely cause
    The voltage difference between battery cells exceeds the alert threshold.
    What to do
    If the battery is connected to the grid, disconnect the AC input, wait for the battery indicator to go out, and then restore the AC input. Reset the system in the app; If the alert persists, contact your distributor or Customer Service.
  • 57criticalCall your installer
    Manual (PDF)

    Low Battery SOH

    Likely cause
    The battery health metric is below the alert threshold.
    What to do
    The battery lifespan has reached its end. Please stop using the battery. Please follow the legal regulations in your country/region and contact local battery recycling services for disposal.
  • 58criticalCall your installer
    Manual (PDF)

    Battery Life Terminated

    Likely cause
    The battery lifespan has reached its end.
    What to do
    The battery lifespan has reached its end. Please stop using the battery. Please follow the legal regulations in your country/region and contact local battery recycling services for disposal.
  • 59criticalCall your installer
    Manual (PDF)

    Battery Micro-Short Circuit

    Likely cause
    The battery micro-short circuit fault occurred.
    What to do
    Please contact your distributor or Customer Service.
  • 60criticalCall your installer
    Manual (PDF)

    Battery Thermal Runaway

    Likely cause
    The battery thermal runaway fault occurred.
    What to do
    Please immediately disconnect the battery AC input and stop using the battery. Please contact your distributor or Customer Service.
  • 62criticalCall your installer
    Manual (PDF)

    Internal Device Error

    Likely cause
    The internal circuit fault protection of the battery is triggered.
    What to do
    In the app, shut down the battery and then power it on again; Reset the system in the app; If the battery is connected to the grid, disconnect the AC input, wait for the battery indicator to go out, and then restore the AC input; If the alert persists, contact your distributor or Customer Service.
  • 64criticalCall your installer
    Manual (PDF)

    Active Device Protection

    Likely cause
    The operating environment of the battery is abnormal.
    What to do
    The device automatically monitors external working conditions and returns to normal after the fault is resolved. If the alert is reported frequently, contact your distributor or Customer Service.
  • 18warningCall your installer
    Manual (PDF)

    High Output DC Voltage Component

    Likely cause
    The output DC voltage component is higher than the upper limit.
    What to do
    The device automatically monitors external working conditions in real time and returns to normal after the fault is resolved. If the fault occurs frequently, contact your distributor or Customer Service.
  • 3warningCall your installer
    Manual (PDF)

    Grid Undervoltage

    Likely cause
    The grid voltage is lower than the lower limit.
    What to do
    Check whether the grid voltage is within the allowed range. If not, contact your local electric system operator. If so, modify the grid undervoltage protection threshold after obtaining consent from your local electric system operator.
  • 4warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    The grid voltage is higher than the upper limit.
    What to do
    Check whether the grid voltage is within the allowed range. If not, contact your local electric system operator. If so, modify the grid overvoltage protection threshold after obtaining consent from your local electric system operator.
  • 5warningCall your installer
    Manual (PDF)

    Grid Underfrequency

    Likely cause
    The grid frequency is lower than the lower limit.
    What to do
    Check whether the grid frequency is within the allowed range. If not, contact your local electric system operator. If so, modify the grid underfrequency protection threshold after obtaining consent from your local electric system operator.
  • 53warningCall your installer
    Manual (PDF)

    Battery Overtemperature

    Likely cause
    The battery temperature exceeds the alert threshold.
    What to do
    Wait for a while and check if the alert disappears automatically. If the alert is reported frequently, please ensure that the working conditions of the device are within the allowed range. If the alert persists, contact your distributor or Customer Service.
  • 54warningCall your installer
    Manual (PDF)

    Low Battery Temperature

    Likely cause
    The battery temperature is below the alert threshold.
    What to do
    Please ensure that the working conditions of the device are within the allowed range. If the alert persists, contact your distributor or Customer Service.
  • 55warningCall your installer
    Manual (PDF)

    Large Battery Cell Temperature Difference

    Likely cause
    The temperature difference between battery cells exceeds the alert threshold.
    What to do
    Shut down the battery and then power it on again. Reset the system. If the alert is reported frequently, contact your distributor or Customer Service.
  • 56warningCall your installer
    Manual (PDF)

    Battery Overcurrent

    Likely cause
    The battery current exceeds the alert threshold.
    What to do
    Wait for a while and check if the alert disappears automatically. If the alert is reported frequently, reset the system in the app. If the alert persists, contact your distributor or Customer Service.
  • 6warningCall your installer
    Manual (PDF)

    Grid Overfrequency

    Likely cause
    The grid frequency is higher than the upper limit.
    What to do
    Check whether the grid frequency is within the allowed range. If not, contact your local electric system operator. If so, modify the grid overfrequency protection threshold after obtaining consent from your local electric system operator.
  • 63warningCall your installer
    Manual (PDF)

    Abnormal Communication Between Battery and Gateway

    Likely cause
    The device is shut down or the CAN bus cable between the device and the gateway is abnormal.
    What to do
    Please ensure that the CAN bus cable between the gateway and battery module is reliably connected. Reset the system. If the alert persists, contact your distributor or Customer Service.
  • 7warningCall your installer
    Manual (PDF)

    High Output Direct Current Component

    Likely cause
    The output direct current component is higher than the upper limit.
    What to do
    The device automatically monitors external working conditions in real time and returns to normal after the fault is resolved. If the fault occurs frequently, contact your distributor or Customer Service.

About Atmoce

Years on the CEC list
Listed on the CEC register
Local support
Not verified
CEC-listed products
4 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$1,875

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is below the smaller-home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 7 kWh battery

How it compares

The Atmoce MS-7K-U-1P + MC100PRO-S1P against the closest-sized batteries from other brands.

Specification
Atmoce MS-7K-U-1P + MC100PRO-S1PAtmoce
Hinen BH7700AHinen
SAJ EK70 BU5-7.0-TVSAJ
Usable capacity?7 kWh7 kWh7 kWh
Continuous power?5 kWNot verifiedNot verified
Peak power?5 kWNot verifiedNot verified
Round-trip efficiency?90%Not verifiedNot verified
Warranty25 yearsNot verifiedNot verified
ChemistryLithium Iron Phosphate(LFP)LFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from Atmoce

Other CEC-approved products from Atmoce available in Australia.

Atmoce Inverters

MS-7K-U-1P

4.5 kW

MS-7K-U-1P + MC100PRO-S1P

4.5 kW

MS-7K-U-3P

4.5 kW · 3φ

MS-7K-U-3P + MC100PRO-T3P

4.5 kW · 3φ

View all Atmoce inverters
View full Atmoce manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?