Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Ambrion
  4. HS2 series
  5. HS2-5K-S2-3 4G

Home battery · Ambrion · HS2 series · CEC approved October 2023

Ambrion HS2-5K-S2-3 4G

CEC listing: HS2-5K-S2-3 4G (AS4777-2 2020)

A 14.25 kWh home battery. Smaller home size, the 10 to 15 kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
14.25kWh
Warranty
10yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

HS2-5K-S2-3 4G: the short answer

In the HS2 seriesThe series' closest fit to the WA rebate cap
14.25kWhThe series' closest fit to the WA rebate cap
WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

Other sizes in the HS2 series

  • 4.75 kWh
  • 9.5 kWh
  • 14.25 kWh (this one)
  • 19 kWh
  • See the whole series →

What we can tell you

Read from the figures on this page. No review written yet.

  • 14.25 kWh sits in the smaller home band (10 to 15 kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
14.25kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
98%
How much of the energy you store comes back out
Warranty
10yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Warranty and support

This warranty covers defects for 10 years. It does not cover damages from improper installation or alterations. To claim, contact support.

Product
10 years; transferable; full replacement
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 4 years on the CEC list. Confirm the claim process with your installer.
Perth heat
Rated to 60°C, which covers Perth's hottest days.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Ambrion HS2, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Nominal capacity
15 kWh
Usable capacity
14.25 kWh
Round-trip efficiency
97.6%

Physical

IP rating
IP65

Operating environment

Operating temperature
45°C to 60°C

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guideOpens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

Fault & error codes — Ambrion HS2

Extracted from the installation manual

34 documented

Showing 34 of 34. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    Master Relay Error

    Likely cause
    Faulty relay connection or malfunction.
    What to do
    Reset the inverter. If the error persists, contact the installer.
  • 10criticalCall your installer
    Manual (PDF)

    Master Phase1 Voltage Low

    Likely cause
    Voltage below acceptable limit on phase 1.
    What to do
    Check the grid and surroundings and contact an electrician if needed.
  • 11criticalCall your installer
    Manual (PDF)

    Master Phase2 Voltage High

    Likely cause
    Voltage exceeds acceptable limit on phase 2.
    What to do
    Check the grid voltage level and contact your installer if issues persist.
  • 12criticalCall your installer
    Manual (PDF)

    Master Phase2 Voltage Low

    Likely cause
    Voltage below acceptable limit on phase 2.
    What to do
    Check the grid and surroundings and contact an electrician if needed.
  • 13criticalCall your installer
    Manual (PDF)

    Master Phase3 Voltage High

    Likely cause
    Voltage exceeds acceptable limit on phase 3.
    What to do
    Check the grid voltage level and contact your installer if issues persist.
  • 14criticalCall your installer
    Manual (PDF)

    Master Phase3 Voltage Low

    Likely cause
    Voltage below acceptable limit on phase 3.
    What to do
    Check the grid and surroundings and contact an electrician if needed.
  • 15criticalCall your installer
    Manual (PDF)

    Grid Voltage 10Min High

    Likely cause
    High grid voltage duration exceeds 10 minutes.
    What to do
    Monitor voltage and contact your installer if it continues.
  • 17criticalCall your installer
    Manual (PDF)

    OffGrid Output Short Circuit

    Likely cause
    Short circuit detected during off-grid operation.
    What to do
    Disconnect load and check for short circuits.
  • 2criticalCall your installer
    Manual (PDF)

    Master EEPROM Error

    Likely cause
    EEPROM failure or corruption.
    What to do
    Power cycle the inverter. If the error does not clear, call for professional assistance.
  • 21criticalCall your installer
    Manual (PDF)

    Phase1 DCV High

    Likely cause
    Direct current voltage on phase 1 exceeds limits.
    What to do
    Check voltages and reduce loads if necessary.
  • 22criticalCall your installer
    Manual (PDF)

    Phase2 DCV High

    Likely cause
    Direct current voltage on phase 2 exceeds limits.
    What to do
    Check voltages and reduce loads if necessary.
  • 23criticalCall your installer
    Manual (PDF)

    Phase3 DCV High

    Likely cause
    Direct current voltage on phase 3 exceeds limits.
    What to do
    Check voltages and reduce loads if necessary.
  • 24criticalCall your installer
    Manual (PDF)

    Master No Grid Error

    Likely cause
    Grid connection lost or unstable.
    What to do
    Check grid connection and restart the system.
  • 25criticalCall your installer
    Manual (PDF)

    DC ReverseConnect Error

    Likely cause
    Reverse connection of DC input detected.
    What to do
    Disconnect and check polarity before reconnecting.
  • 27criticalCall your installer
    Manual (PDF)

    GFCI Error

    Likely cause
    Ground Fault Circuit Interrupter has detected a fault.
    What to do
    Reset GFCI and check wiring.
  • 3critical
    Manual (PDF)

    Master Temperature High Error

    Likely cause
    Overheating of the master unit.
    What to do
    Turn off the unit and allow it to cool. Check ventilation before restarting.
  • 31criticalCall your installer
    Manual (PDF)

    ISO Error

    Likely cause
    Insulation fault detected in the system.
    What to do
    Disconnect and inspect for insulation failures.
  • 8criticalCall your installer
    Manual (PDF)

    Current Sensor Error

    Likely cause
    Sensor malfunction or disconnection.
    What to do
    Inspect sensor connections and replace if faulty.
  • 9criticalCall your installer
    Manual (PDF)

    Master Phase1 Voltage High

    Likely cause
    Voltage exceeds acceptable limit on phase 1.
    What to do
    Check the grid voltage level and contact your installer if issues persist.
  • 16warning
    Manual (PDF)

    OffGrid Output Voltage Low

    Likely cause
    Output voltage is below threshold when operating off-grid.
    What to do
    Check load and restart the system.
  • 18warning
    Manual (PDF)

    Master Grid Frequency High

    Likely cause
    Grid frequency exceeds safe operational limits.
    What to do
    Reduce load and wait for frequency to return to normal.
  • 19warning
    Manual (PDF)

    Master Grid Frequency Low

    Likely cause
    Grid frequency falls below safe operational limits.
    What to do
    Increase load and wait for frequency to return to normal.
  • 20warningCall your installer
    Manual (PDF)

    BATInputMode Error

    Likely cause
    Input mode error in battery configuration.
    What to do
    Check battery connections and input modes.
  • 26warningCall your installer
    Manual (PDF)

    Parallel machine CAN Com Error

    Likely cause
    Communication failure in parallel machine setup.
    What to do
    Check CAN connection and restart units.
  • 28warningCall your installer
    Manual (PDF)

    Phase1 DCI Error

    Likely cause
    Current input issue on phase 1.
    What to do
    Inspect current sensor for faults.
  • 29warningCall your installer
    Manual (PDF)

    Phase2 DCI Error

    Likely cause
    Current input issue on phase 2.
    What to do
    Inspect current sensor for faults.
  • 30warningCall your installer
    Manual (PDF)

    Phase3 DCI Error

    Likely cause
    Current input issue on phase 3.
    What to do
    Inspect current sensor for faults.
  • 32warning
    Manual (PDF)

    Bus Voltage Balance Error

    Likely cause
    Imbalance detected in bus voltage levels.
    What to do
    Power cycle the system and monitor voltage balance.
  • 33warning
    Manual (PDF)

    Master Bus Voltage High

    Likely cause
    Bus voltage exceeds allowable limit.
    What to do
    Reduce load and check voltage outputs.
  • 34warning
    Manual (PDF)

    Master Bus Voltage Low

    Likely cause
    Bus voltage below safe levels.
    What to do
    Check connections and increase load if necessary.
  • 4warning
    Manual (PDF)

    Master Temperature Low Error

    Likely cause
    Temperature below operating range.
    What to do
    Warm up the unit to normal operating temperature before restarting.
  • 5warningCall your installer
    Manual (PDF)

    Lost Communication M<->S

    Likely cause
    Communication failure between master and slave units.
    What to do
    Check connections and reboot the inverter.
  • 6warningCall your installer
    Manual (PDF)

    GFCI Device Error

    Likely cause
    Ground Fault Circuit Interrupter malfunction.
    What to do
    Reset the GFCI. If the issue continues, consult an electrician.
  • 7warning
    Manual (PDF)

    DCI Device Error

    Likely cause
    Error in the direct current input.
    What to do
    Inspect DC circuit for faults and restart the system.

About Ambrion

Years on the CEC list
4+ (CEC-approved products since 2022)
Local support
Available
CEC-listed products
60 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$3,830

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the smaller home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 14.25 kWh battery

How it compares

The Ambrion HS2-5K-S2-3 4G against the closest-sized batteries from other brands.

Specification
Ambrion HS2-5K-S2-3 4GAmbrion
Jeeseng JEEDD-153100Jeeseng
Red Earth Energy Storage SRS-318Red Earth Energy Storage
Usable capacity?14.25 kWh14.28 kWh✓highest14.2 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?98%Not verifiedNot verified
Warranty10 yearsNot verifiedNot verified
ChemistryLFPLFPNot verified

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from Ambrion

Other CEC-approved products from Ambrion available in Australia.

Ambrion Inverters

AS1-3KS-10.2

3 kW

AS1-3KS-15.3

3 kW

AS1-3KS-20.4

3 kW

AS1-3KS-5.1

3 kW

AS3-10K-T-W-P10-AUS

10 kW · 3φ

AS3-10K-T-W-P2-AUS

10 kW · 3φ

View all Ambrion inverters
View full Ambrion manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?